DAA PRIMAFILL Primer feeder - DOUBLE...

DAA PRIMAFILL Primer feeder - DOUBLE ALPHA

Art. OM-DAAPRIMAFILL
€106.85
Tax included
DAA PRIMAFILL Primer feeder - DOUBLE ALPHA

 
Double-Alpha PRIMAFILL is a solution for semi-automatic primer tube filling, it is able to quickly and easily fill both small and large primer tubes. It allows you to instantly switch between Small and Large primers, without tools or assemblies . The PRIMAFILL can be used with any primer tube that has an outside diameter of 8mm, such as Dillon or DAA tubes. It does not require a custom tube mounted adapter as other competing products require. So using PRIMAFILL you can fill all your tubes with primers! The Extra-Large Flip Tray area is convenient when emptying large primers, such as Federal and others. The tray is large enough to hold the entire box. The PRIMAFILL is powered by a normal 9v battery (not included). The power switch is located under the index finger while holding the device using it with the right hand, with the thumb centered on the top of the lid. Press and hold the button as you insert the primers into the tube and release as soon as the last primer vanishes into the outlet hole. Since this action should take 20 seconds or less, a battery charge will last for many thousands of triggers. The spring-loaded orange latches built into the output risers allow you to snap a tube into place or remove it, instantly without twisting or twisting, the latch naturally falls under your thumb - pressing it while inserting the tube up or pressing the stop as you pull the tube down. An easy and natural thumb action. Primer and battery tubes are not included! Instructions for Use: Make sure a 9V battery is inserted and test by pressing the button. The device should vibrate and hum gently in your hand. Do not remove the foam pad from under the battery, it is necessary there. Remove the cover and place the magnetic holding cap to block the LARGE or SMALL outlet hole according to your needs. Turn it over when moving it from side to side. Place PRIMAFILL on a flat table and place 100 primers on the tipping tray area. With the device resting on a smooth table top, swipe it in short, brusque movements to flip all primers until they are all with the anvil facing up. Replace the lid and insert a tube of primer into the appropriate outlet hole. Push down on the orange latch as you push the tube into place and make sure it is seated as far as it will go. Hold the device in your right hand, with your index finger on the button and your thumb centered on the lid. Tilt PRIMAFILL so primers cluster near the LOCKED outlet hole (hence from LARGE when feeding SMALL primers) Activate the vibrating motor by pressing and holding the power button, then gradually tilt the device towards the open outlet hole (right for SMALL primers) so that a single (or at most a double) row forms towards the hole exit. Also tilt the device towards you to help the primers slide down the exit channel to the exit hole. Do not tilt more than necessary on one of the axes. Try to keep PRIMAFILL as horizontal as possible, while still creating enough movement in the primers. Note that: Different brands of inneschir tip better with different types of shaking motion of the tipping tray. Experiment to find the optimal turntable action required to flip your hookbaits. Various types of primers flow differently, at different speeds. Some require you to hold the device at a steeper angle to get them to move properly. Experiment a little to find the correct feed angle best for your hookbaits. If a trigger gets stuck on the exit hole, a tap with your left finger on the top of the lid above the hole should immediately clear it. There is no need to stop the device from vibrating or remove the cover. some primer tubes have an ill-formed or non-symmetrical inlet hole chamfer, this can create a protrusion that the primers can intercept as they fall into the tube by braking inside. In this case it is recommended to use the other end of the tube. Or try rotating the tube to find the angle that allows the trigger wings to flow uninterrupted completely in the tube. It is recommended to mark it with a marker on the tube, so that it can be easily repositioned in the same way. Primer tubes are NOT included with the device, in order to reduce cost and packing size. Product Dimensions and Weight
DOUBLE ALPHA

16 other products in the same category:

Product added to wishlist
Product added to compare.